Setting change accumulation options

If you specify Y in the Execute Change Accum field, you can also specify Y in the Edit Options field to further customize change accumulation options.

About this task

Complete the following steps to edit index rebuild options:

Procedure

  1. On the Recovery Options panel, specify Y in the Edit Options field next to Execute Change Accum, and press Enter.
  2. On the Change Accumulation Utility Options panel, specify the following information:
    Figure 1. Change Accum Utility Options panel
    IMS RE   V2R2 -------- Change Accum Utility Options ------- 2021/04/17 12:45:0 
    Option   ===>                                                                  
    -------------------------------------------------------------------------------
     Creator: ******     Name: BSY.DEMO                          SSID: IDA          
     Share Option: U  (Upd,View,No)    Description: TEST                           
    -------------------------------------------------------------------------------
    Enter the options for the change accumulation utility:                         
                                                                                   
     GENJCL member name      ==> BSYHPCA                                           
     Run CA                  ==> A  (Always/as Needed)                             
                                                                                   
     Datasets for GENJCL     ==> TSMXD.BSY.DEMO.JCLPDS                             
                             ==> IMSQA.BSY220.DATA.JCLPDS                          
                             ==> ____________________________________              
                             ==> ____________________________________              
                             ==> ____________________________________              
                                                                                   
    GENJCL member name
    Specify a skeleton member name to use for Change Accumulation JCL generation.
    Run CA
    Specify whether or not you want to run change accumulation before database recovery. Specify A to always run change accumulation. Specify N if you want IMS Recovery Expert to run change accumulation only if it is required for recovery.
    Datasets for GENJCL
    Displays the concatenation of data sets for GENJCL member selection.
  3. Press Enter, or specify END on the Option line to return to the Recovery Options panel, or specify CAN to cancel.