18-Verifying IMS Online System initialization

Modifications are required in all the IMS subsystems that use IMS Tools Generic Exits, IMS Tools Online System Interface, and the Recovery Point Create (RPCR) feature. You must ensure that each online system is recycled with the required changes. A successful initialization is indicated by a series of messages.

The following sections contain examples of messages that you should see for each component and product.

IMS Tools Generic Exits initialization

If IMS Tools Generic Exits have been successfully installed in all the IMS control regions that use this interface, the following "GPR" messages will be issued in those IMS control regions:
GPR2926I IMS Tools Generic Partner Exit INITIALIZATION IN PROGRESS 
GPR2926I PROCESSING PROCLIB MEMBER GPROPT0  imsi
GPR2926I PROCESSING PROCLIB MEMBER GPRimsi0   imsi
GPR2926I IMS Tools Generic Partner Exit INITIALIZATION COMPLETE

IMS Tools Online System Interface initialization

If the IMS Tools Online System Interface has been successfully installed in all IMS control regions that use this interface, the following messages will be issued in those control regions:
DFS0578I - READ SUCCESSFUL FOR DDNAME PROCLIB  MEMBER = FOIimsiP 
FOI100I TOOLS ONLINE INTERFACE ENABLED; XCF GROUP=TOIxcfgr  imsi
After these messages are issued, verify that your group names were configured properly:
  • Ensure that the XCF GROUP= group name is the same name that is specified in the various tools that you have already configured.
  • Ensure that all IMS subsystems that are supposed to be in the same group all have the same XCF GROUP= group name.

Recovery Point Create initialization

If the Recovery Point Create feature has been successfully installed in all the IMS control regions that use this product, the following "IRO" messages will be issued in those control regions:
IRO8100I Recovery Point Create initialization for  imsi  completed