Setting data set options
If you plan to allow IMS Recovery Expert to offload backups, you must set data set names and other specifications for the offloaded data sets.
Procedure
- On the Offload Options panel, specify Y in
the appropriate backup type field (Local Primary, Local
Backup, Recovery Site Primary,
or Recovery Site Backup) and press Enter.
Note: When you later edit a profile, specify U in the appropriate backup type field and press Enter.
Figure 1. LP Offload panel (BSY$OFF2) BSY$OFF2 V2R2 ----------- LP Offload Options ----------- 2021/11/11 13:56:23 Option ===> ------------------------------------------------------------------------------- Creator: CSTSUK Name: DFSMSDSS BACKUP METHOD SSID: I9A2 Share Option: U (Upd,View,No) Description: DFSMSDSS BACKUP METHOD ------------------------------------------------------------------------------- Update DSN Specification => N (Yes/No) Unit Type => CART (CART/SYSALLDA/etc.) Catalog => Y (Yes/No) Data Class => (8 character class) Storage Class => (8 character class) Management Class => (8 character class) Tape specific parameters (only needed if Unit Type is a Tape device): Stack Backups on Tape => Y (Yes/No) Tape Stack Limit => 005 (1 - 999) Expiration date *or* => (YYYYDDD/YYDDD) Retention period => 1234 (4 digit number) Maximum Tapes => 005 (1-256)
On the Offload panel, the header fields Creator, Name, SSID, Share Option, and Description that identify the profile are read-only.
- Specify information in the following fields:
- Update DSN specification
- Specify Y in this field to set or change the data set specifications.
- Unit Type
- Specify a valid UNIT where the data set(s) will be written.
- Catalog
- Specify Y to catalog the data sets. Specify N if you do not want to catalog the data sets.
- Data Class
- If your site uses SMS to manage data sets, specify the SMS data class.
- Storage Class
- If your site uses SMS to manage data sets, specify the SMS storage class.
- Management Class
- If your site uses SMS to manage data sets, specify the SMS management class.
- Tape specific parameters
- If Unit Type is a tape device, specify tape specific parameters in this field.
- Stack Backups on Tape
- Specify whether you want to stack backups on a single tape when possible.
- Tape Stack Limit
- If stacking backups, specify the number of volumes that you want IMS Recovery Expert to stack on one tape before dismounting the tape.
- Expiration date *or* Retention period
- If the unit type specified in the Unit Type field is a tape device, specify either the tape expiration date in YYYYDDD format, or the tape retention period as the number of days.
- Maximum Tapes
- Specify the maximum number of volumes to use for each volume offload file.