FABJ0221W ERROR OCCURRED IN ACCESSING OUTPUT REPOSITORY FUNC: function RC: rc RSN: rsn

Explanation

An error occurred while getting access to the IMS Tools KB Output repository.

System action

Processing continues. If the return code is equal to or greater than 08, IMS HP Image Copy does not store its reports to the IMS Tools KB Output repository.

User response

If you want to store the reports to the IMS Tools KB Output repository, correct the error.

If you receive this message in an IMS Online Reorganization Facility job, ensure that the server name is specified correctly. If the processed database is a HALDB, ensure that the ITKBSERVER keyword is specified in the HRFSYSIN DD of IMS Online Reorganization Facility.

Problem determination

If any of the messages, FABJ0227W, FABJ0228W, FABJ0229W, or FABJ0230W, which describes the cause of the error, is issued following this message, see the explanation for those messages. If those messages are not issued, check the return code and the reason code shown in this message. The codes are in hexadecimal. For the description of the return code and reason code, see the IMS Tools Base IMS Tools Knowledge Base User's Guide and Reference.