FABJ0220W THE ACCESS TO OUTPUT REPOSITORY WAS CANCELED REASON: reason

Explanation

IMS HP Image Copy canceled its access to the IMS Tools KB Output repository because the initialization process failed. The reason is one of the following:

  • Dynamic allocation of the library in the ITKBLOAD parameter failed
  • Failed to open the library specified on the ITKBLOAD parameter
  • Failed to load the HKTXXLI module

System action

Processing continues, but IMS HP Image Copy does not store any reports to the IMS Tools KB Output repository.

User response

If you want to store the reports to the IMS Tools KB Output repository, specify the correct load module library of the IMS Tools KB product.

Problem determination

Check the following to see if the IMS Tools KB product load module library name is correct:

  • The specification of the ITKBLOAD parameter on the PROC statement in the PROCCTL data set
  • STEPLIB, JOBLIB, or LINKLIST concatenations