BBE3213E BLDL FAILED. RC=return_code, RSN=reason_code, DD: ddname, MEMBER: member, MOD: modname, ERROR-ID: error_id

Explanation

The BLDL macro failed with return code return_code and reason code reason_code. member indicates the name of the member that caused the failure. modname and error_id indicate the location and cause of the error.

System action

DB Sensor processing ends with return code 8.

User response

Check the data set that is specified by the ddname DD to see if the member is included in the data set. If the member is included in the data set, identify the cause of the BLDL failure by determining the meaning of the return code and reason code, which are documented in z/OS® DFSMS Macro Instructions for Data Sets. Correct the error and rerun the job. If the error is not in the data set or your system, contact IBM® Software Support.