HPC4014W PITCA processing failed for grpname
STORAGE OBTAIN failed for CA/PITCA DCBs RC=rc
Explanation
After determining a change accumulation (CA) could be used to establish a point in time change accumulation (PITCA), the process failed when a request was issued for storage to build the input CA and output PITCA data set DCB structures.
This request is made for storage below the 16M line and is likely caused by storage constraints on the system.
The return code for the STORAGE OBTAIN request was rc.
System action
The IMS HP Change Accumulation job completes with the highest return code issued for all CA Groups being processed.
If this is the only CA Group being processed, the job completes with RC=8.
No PITCA is created for CA Group grpname.
User response
Reference the z/OS® MVS Programming: Authorized Assembler Services Reference, chapter "STORAGE — Obtain and release storage", section "Return and reason codes" to determine the cause of the failure.
Contact your MVS™ Systems Programmers and IBM® Software Support as needed.