Repositioning columns

The CORDER option enables you to reposition report columns.

About this task

If any columns are fixed, they are grouped together as the leftmost report columns. The unfixed columns are grouped together to the right of any fixed columns. CORDER does not move a column out of its group. A fixed column cannot be relocated to the right of an unfixed column. Likewise, an unfixed column cannot be relocated to the left of a fixed column.

Procedure

  1. Specify CORDER on the Option line on any display panel and press Enter.
    Figure 1. Define Column Display Order panel (BSYORD)
     BSYORD --------- Define Column Display Order ---------  2021/11/11 11:56:37
     Option  ===>                                               Scroll ===> PAGE
     Commands: Enter: Process selections                                            
     Cmd: Specify number for column position                                        
     ------------------------------------------------------------------------       
                                                                     ROW 1 OF 6 
                                                                                    
     Column Function ===> 2 (1-Fix/Unfix, 2-Order, 3-Size, 4-Sort)                  
     Permanent View  ===> Y (Y-Perm, N-Temp)  Reset View ===> N (Y,N)               
                                                                                    
                                                                                    
     Cmd Fix New Old Column_Name                                                    
         P         1 CMD                                                            
                   2 SOURCE_VOLUMES                                                 
                   3 SOURCE_DEVTYPE                                                 
                   4 SOURCE_UNIT                                                    
                   5 TARGET_VOLUMES                                                 
                   6 MESSAGE_AREA                                                   
     
    On the Define Column Display Order panel, the following fields are displayed:
    Column Function
    Enables you to jump to any of the CSET functions by typing in the appropriate number. The number corresponding to the current option displays in this field.
    Permanent View
    Indicates whether the CSETUP customization you define is permanent or temporary. CSETUP customization refers to the change made in the CSETUP functions CFIX, CORDER, CSIZE, and CSORT. These customizations are called views. Valid values are: Y (CSETUP customization is permanent), or N (CSETUP customization is temporary).
    Reset View
    Resets all customizations.
    Cmd
    In the Cmd field, you can specify the number for column position.
    Fix
    Displays fixed columns. Valid values are: F (indicates that the column is fixed) or P (indicates that the column is permanently fixed).
    New
    Displays the new CORDER view settings.
    Old
    Displays the previous CORDER view settings.
    Column_Name
    Displays the name of the column.
  2. Specify a number next to a column to specify its order.
  3. Press Enter.
    The new column order numbers display in the New column next to each column.
  4. Press PF3 to return to the display panel.