FRD4306I VSAM READ | WRITE LOGICAL | PHYSICAL ERROR: RC=xx RSN=yy DDNAME=nnnnnn WITH

Explanation

During a data set restore process, an I/O error was encountered. This message is accompanied with FRD4100I to identify the data set that experienced the error. In the message text the following values apply:
xx
The return code returned by VSAM
yy
The reason code returned by VSAM
nnnnnn
The DDN the data set was allocated under

System action

Recovery for this DBD and DDN stops. If the ERRORCONT parameter was not specified on the START command, the entire recovery process stops.

User response

For an explanation of the return and reason code, see the z/OSĀ® DFSMS Macro Instructions for Data Sets manual. Take the appropriate action indicated by the return and reason codes.

Module

FRXIVCN0, FRXIVSM0