FRD4230I VSAM SHOWCB GENCB MODCB POINT MACRO ERROR, BLOCK=block, RC=xx, RSN=yy
Explanation
During a data set restore process, a VSAM macro error occurred for either a
SHOWCB, GENCB, MODCB, or POINT. In the message text the following values apply:
- block
- Identifies the VSAM control block being generated or modified.
- xx
- The return code returned by VSAM.
- yy
- The reason code returned by VSAM.
System action
Recovery for this DBD/DDN (as identified by message
FRD4301I that follows this message) stops. If ERRORCONT was not specified
on the START
command, the entire recovery process
stops.
User response
For an explanation of the return and reason code, see the interpreting DYNALLOC return codes information in the z/OS® MVS Programming: Authorized Assembler Services Reference, Volume 1 (ALE-DYN). Take the appropriate action indicated by the return and reason codes.
Module
FRXIVCN0, FRXIVSM0