BPE0013E VERSION MISMATCH BETWEEN BPE AND FRD
BPE MODULE VERSION IS bver.brel.bptrel
FRD WAS ASSEMBLED AT BPE VERSION pver.prel.pptrel

Explanation

The IMS Database Recovery Facility BPE version on which IMS Database Recovery Facility was built does not match the version of the IMS Database Recovery Facility BPE modules that were loaded.

This can occur, for example, if IMS Database Recovery Facility was assembled at one IMS Database Recovery Facility BPE version and the your STEPLIB data set contained IMS Database Recovery Facility BPE modules at a different IMS Database Recovery Facility BPE level.

This is a three-line message. Each line begins with the message number.

In the message text:
bver
The version number of IMS Database Recovery Facility BPE modules
brel
The release number of IMS Database Recovery Facility BPE modules
bptrel
The point-release number of IMS Database Recovery Facility BPE modules
pver
The version number of IMS Database Recovery Facility BPE macros at which IMS Database Recovery Facility was assembled
prel
The release number of IMS Database Recovery Facility BPE macros at which IMS Database Recovery Facility was assembled
pptrel
The point-release number of IMS Database Recovery Facility BPE macros at which IMS Database Recovery Facility was assembled

System action

IMS Database Recovery Facility BPE ends abnormally during early initialization with abend U3400, subcode X'09'.

User response

This problem is probably caused by a mismatch with your STEPLIB data set. Ensure that IMS Database Recovery Facility is using the correct version of the your STEPLIB data set.

Module

FRXINIT$