FABHFSU PSF Scan Control Data Set report
This report contains information about the parameters specified on the CARDIN control statements that were input to the scan control data set. This report is produced for each output data set defined by the PSB control statement in the CARDIN data set.
The following figure shows an example of this report.
IMS HIGH PERFORMANCE UNLOAD "FABHFSU PSF SCAN CONTROL DATA SET REPORT" PAGE: 1
5655-E06 DATE: 06/01/2021 TIME: 12.52.06 FABHPSFC - V1.R2
*** SCAN CONTROL SPECIFICATIONS *** *** FORMAT CONTROL SPECIFICATIONS ***
PARALLEL SCAN NAME SCANCNTL FORMAT (CONTROL PSB) NUMBER 01
BASE DBD NAME MSHDP CONTROL PSB NAME *
INDEX DBD NAME CONTROL PCB NUMBER
SEQUENCE CHECK OPTION NO OUTPUT DDNAME OUT1
SEQUENCE ERROR OPTION N.A OUTPUT FORMAT UL
SEQUENCE ERROR PRINT OPTION N.A EXIT ROUTINE NAME N.A
SEQUENCE ERROR THRESHOLD N.A SEGMENT MODIFICATION OPTION N.A
SEQUENCE ERROR ABEND OPTION N.A CONCATENATED KEY OPTION N.A
EXIT OPEN/CLOSE CONTROL N.A
LIMIT CONTROL YES DBR SKIP OPTION N.A
POINTER BYPASS OPTION NO EXIT LE OPTION N.A
NO. PARALLEL SCANS 05
DSN CHECK OPTION NO
PSC WTO OPTION NO
SEP HEADER OPTION NO
IMS HIGH PERFORMANCE UNLOAD "FABHFSU PSF SCAN CONTROL DATA SET REPORT" PAGE: 2
5655-E06 DATE: 06/01/2021 TIME: 12.52.06 FABHPSFC - V1.R2
**** PHASE CONTROL SPECIFICATIONS ****
PHASE 01 STARTING BLOCK BEGINNING OF FILE
ENDING BLOCK 809
PHASE 02 STARTING BLOCK 810
ENDING BLOCK 1,619
PHASE 03 STARTING BLOCK 1,620
ENDING BLOCK 3,239
PHASE 04 STARTING BLOCK 3,240
ENDING BLOCK 4,859
PHASE 05 STARTING BLOCK 4,860
ENDING BLOCK END OF FILE
- SCAN CONTROL SPECIFICATIONS
- Shows specifications or defaults from CTL and DBD control statements.
- FORMAT CONTROL SPECIFICATIONS
- Shows specifications or defaults from PSB control statement.
- PHASE CONTROL SPECIFICATIONS
- Shows starting and ending block values of each scan phase based on specifications from NPT control statement.