FABG3506E INVALID HISTORY DATA SET ENTRY WAS FOUND FOR DBNAME: dbname

Explanation

The system found an incorrect HISTORY data set entry while processing HISTORY data set records for the database (dbname). An incorrect HISTORY data set entry might be created when HD Pointer Checker run fails during processing a database data set group associated with the database.

System action

The system ends with an abend code of 3506.

User response

Run DB Historical Data Analyzer with the TYPE=LIST option, and generate the HISTORY Data Set by Key Date report and HISTORY Data Set by DB-DS report.

Collect database data sets and key date information of the incorrect HISTORY data set entries, prepare necessary DB Historical Data Analyzer control statements, then delete these incorrect entries by running DB Historical Data Analyzer with the TYPE=DELETE option. Rerun the job.