HPSR0311W THE ACCESS TO OUTPUT REPOSITORY WAS CANCELED. REASON: reason

Explanation

IMS HP Load canceled its access to the IMS Tools KB Output repository because initialization process failed. The list describes the reason:

Reason Meaning
ITKBLOAD DYNALLOC FAILURE Dynamic allocation for the library that is specified on the ITKBLOAD control statement failed.
HKTXXLI LOAD FAILURE Loading of the HKTXXLI module failed.
ITKBLOAD OPEN FAILURE Opening of the library that is specified on the ITKBLOAD control statement failed.
ITKBLOAD NOT AUTHORIZED The library that is specified on the ITKBLOAD control statement is not APF-authorized.

System action

Processing continues, but none of the reports are stored in the IMS Tools KB Output repository.

User response

If you want to store reports in the IMS Tools KB Output repository, specify the IMS Tools KB product load module library correctly. If the reason is "ITKBLOAD NOT AUTHORIZED", the library must be APF-authorized.