FABX0567W DBD resource1 IS NOT REFERRED BY [DBD|PSB] resource2.
Explanation
The DBD or PSB resource2 being processed does not refer to its
related DBD resource1 because the Catalog Manager utility cannot
identify the resource1 instance from the IMS catalog database
when one of the following conditions is met:
- resource2 is not an Active or Pending instance.
- When resource2 has a database versioning number and some of the DBD instances with the same database versioning number exist in the IMS catalog database, the timestamp of resource2 is not the latest.
- When resource2 is a LOGICAL DBD and some of the DBD instances of this LOGICAL DBD instance exist in the IMS catalog database, the timestamp of resource2 is not the latest.
System action
IMS Library Integrity Utilities continues processing without referencing resource1.