FABL3011E THE DBRC USER EXIT LIST IS INCORRECT FOR LIU INTEGRITY CHECKER
Explanation
The DBRC user exit list member of the IMS PROCLIB data set is incorrect for the Integrity Checker utility. The Integrity Checker utility is not specified as a DBRC request user exit.
System action
The IMS online subsystem continues processing with the Integrity Checker utility deactivated.
User response
Verify that the FABLBIN0 module is specified by using the EXITDEF statement of the DBRC user exit list member in the IMS PROCLIB data set. Also verify that the module is specified as a DBRC request user exit. Correct the DBRC user exit list member and restart the IMS online subsystem. For instructions for configuring IMS PROCLIB, see Configuring for a BPE-based DBRC environment. Do not issue the BPE USEREXIT command until you restart the subsystem.