FABJ3943E A SYSTEM ABEND WAS DETECTED BECAUSE INCORRECT SVC NUMBER nnn IS USED. SUBSYSTEM RECORD SSID=ssid MAY REMAIN IN DBRC.

Explanation

The system detected an incorrect type 2 supervisor call (SVC) number (nnn). The type 2 SVC number that is defined in the IMS Installation Defaults module (DFSIDEF0) does not match the SVC number in the IMS system. The SUBSYS record for the IMS subsystem ID (ssid) might remain in the DBRC RECON data sets.

System action

The Image Copy function ends with an abend code of 3943.

User response

Specify a correct type 2 SVC number by using the DFSIDEF macro of the DFSIDEF0 module and rebuild the DFSIDEF0 module. Also, run the LIST.SUBSYS SSID(ssid) command of DBRC and check whether the subsystem record exists or not. If the record remains in the DBRC RECON data sets, delete the record by issuing the following commands:
  • CHANGE.SUBSYS SSID(ssid) STARTRCV
  • CHANGE.SUBSYS SSID(ssid) ENDRECOV
  • DELETE.SUBSYS SSID(ssid)