FABC3953E ERROR IN CALL TO RANDOMIZER xxxxxxxx subtext
Explanation
Program FABCUR6 called the specified randomizer
module to calculate the new area and RAP number values for a root
segment. The values returned were invalid. One of the following subtexts
is issued:
- FUNCTION: function_name
- RETURN CODE: xxxx REASON CODE: X'xxxxxxxx' - - INVALID AREA #, RAP # VALUES RETURNED FOR SEG AT RBA xxxxxxxx
(VALUES RETURNED: AREA #: xxxxx, RAP #: xxx,xxx,xxx)
"FUNCTION" and "REASON CODE" are issued only when FABCUR6 called the XCI randomizer routine.
System action
FABCUR6 ends with an abend code of 3953.
User response
Verify that the RMODLIB DD statement specifies the correct data set. Correct the errors, and rerun the job. If this situation persists, report it to database administration personnel.