FABA0168E SEGMENT AT RBA: xxxxxxxx (SEGCD: yy) HAS AN INVALID LENGTH OF SEGMENT
Explanation
Program FABADA1 encountered a segment with an incorrect length during the serial "deblocking" of the CI. The length value is out of the range between the minimum length and the maximum length defined in DBD. If it is a compressed segment, it is out of the range and is in between 3 and the maximum length added by 10.
System action
FABADA1 sets an end-of-job return code of 99, and continues processing.
User response
Correct any errors, and rerun the job. If this situation persists, report it to systems operations personnel.