BBE3251E GETMAIN FAILED WITH RC=return_code (SIZE=size) IN modname MODULE, ERROR-ID: error_id
Explanation
DB Sensor failed to obtain storage. size indicates the size of the storage that could not be obtained. The hexadecimal value return_code shows the return code that is returned from the GETMAIN macro. modname indicates the name of the failed module, and error_id indicates the error ID that is associated with the module.
System action
DB Sensor processing ends with return code 8.
User response
See the MVS Programming: Assembler Services Reference to determine the meaning of the return code. Correct the error and rerun the job. If the problem persists, contact IBM® Software Support.