FABC3945E PARENT SEGMENT CODE FIELD IN USR PREFIX IS INCORRECT FOR AREA NO: nnnnn, AREANAME: areaname.
- USR REC# : xxx,xxx,xxx
- SEGCODE : xxx
- USR PARENT SEGCODE : xxx
- DBD PARENT SEGCODE : xxx

Explanation

Program FABCUR3 detected that the segment code in the USRPSCD field of the unloaded segment record specified by the record number (REC#) was not correct. First child segment record must have its parent segment code in the USRPSCD field. Second or subsequent twin segment record must have its same segment code.

System action

FABCUR3 ends with an abend code of 3945.

User response

Check the content of the unloaded segment record specified by the record number (REC#), correct the value of the USRPSCD field, and rerun the job.