IIS-CONN-DB2-00429W All of the Db2 client library properties for the conductor node must be the same. The conductor will use the Db2 client library from the first Db2 connector stage in the job. The conductor will use Db2 client library value of the first Db2 Connector stage.

Explanation

There are multiple Db2 Connector stages in the job and the Db2 client library property for the conductor node must be the same in every Db2 Connector stage. Because there are different Db2 client libraries specified in the job for the conductor node, the connector will use the Db2 client library specified in the first stage in the job.

User response

Change the Db2 client library property to be the same for all Db2 Connector stages in the job. Alternatively, set the Alternate conductor settings property to Yes and specify the same value for the Alternate conductor settings->Db2 client library property for all Db2 Connector stages in the job.