Synchronization Interval

Use this system parameter to set how often (in seconds) CDC Replication performs log synchronization between the source and the target.

Versions supportedCDC Replication Engine for Db2® for i version 6.1 and later

Synchronization is achieved when the source reports to the target the position of the last committed change.

If you are replicating large volumes of data, set this system parameter to a smaller number of seconds to remove obsolete logs more frequently.

Applies to
Source datastores
Minimum Settings
1 second
Maximum Settings
3000 seconds (50 minutes)
Default Setting
60 seconds