Use this system parameter to enable or disable CDC Replication from
generating a message each time it detects an invalid numeric field.
Versions supported—CDC Replication Engine for Db2® for
i version 6.1 and later
- Applies to
- Target datastores
- Values
- Set this parameter to one of the following
values:
- *YES
- CDC Replication generates
a message for each invalid numeric field detected.
- *NO
- CDC Replication does
not generate a message for each invalid numeric field detected.
- If you are sure that numeric data does not have to be validated,
set this parameter to *NO to maintain existing performance levels.
- *NB
- CDC Replication does
not generate a message when blank or uninitialized numeric fields
are detected. Messages for other types of invalid numeric data are
still generated.
- Default Setting
- *YES