INACTTHRESHOLD
INACTTHRESHOLD is an optional parameter that defines the frequency for issuing the inactivity message CECZ0400W for a given subsystem.
Description
In an IMS data sharing environment, changes are captured from multiple DB/DC or DBCTL subsystems. The CECZ0400W message is issued in situations where the activity of one or more subsystems is not detected for an extended period of time.
The value that you specify for the INACTTHRESHOLD parameter controls how frequently the CECZ0400W message is issued. You can specify any value, in seconds, between the minimum value of 1 and the maximum value of 86400 (24 hours). The new value takes effect after the previous INACTTHRESHOLD value is reached.
Specifications
Use: Configuration parameter for the IMS log reader service.
Service class: LRSI
Task name: CECLRS
Data type: INT
Default: 30s
Valid values: 1s - 86400s