CHC9510W
CHC9510W TCP/IP maxdesc() service call could only set number socket handles.
Explanation—During initialization, CDC Replication issued a TCP/IP maxdesc service function call to set the maximum number of sockets that can be used by CDC Replication. The maximum number of sockets permitted by TCP/IP is lower than the number of sockets that was requested. This message indicates that a diminished number of sockets are available to CDC Replication, as indicated by the TCP/IP maxdesc service function call.
Message Variables:
number—The number of sockets that can be used by CDC Replication, as indicated by the TCP/IP maxdesc service function call.
Message Destination—System log
System Action—CDC Replication continues executing, but with a reduced capability to communicate with a large number of subscriptions.
Operator Response—This message should be conveyed to the system programmer who is responsible for TCP/IP. If the problem is corrected, CDC Replication must be stopped and then restarted again in order to regain the use of all available sockets.
Client Administrator Response—None