CECZ0993E (0x011003E1) CECZ0993E The IMS change-capture interface received a DL/I end notification for job job-name that is not recorded in the RECON.
Explanation
A DL/I job step ended and the IMS logger exit notified the IMS change-capture interface that job-name produced data capture log records and the job must be included in ordering decisions.
When the end notification is received, the IMS change-capture interface calls DBRC to obtain information about the log data set for the IMS system that is created by the job step. This error is issued when no PRILOG tracking entry is found in the RECON that is being accessed by the source server.
The end notification is ignored by this source server. In this situation there are likely multiple IMS data-sharing environments (multiple RECONs) running in the same sysplex environment and multiple source servers.
The CECE1OPT module that is referenced by the identified job is configured incorrectly and should be notifying a different source server. In this case the source server that is accessing the RECON that is tracking this job does not capture the changes that are produced by the job, which is likely to result in replication failure or target database corruption.
Another unintended consequence is that the source server that mistakenly got the notification stopped processing changes when the start notification was received from this job.
User response
Update the CECE1OPT module that is referenced by this job to reference the IP address and port number of the correct source server.