Configuring a queue manager for telemetry on Windows
Follow these manual steps to configure a queue manager to run IBM® MQ Telemetry. You can run an automated procedure to set up a simpler configuration using the IBM MQ Telemetry support for MQ Explorer.
Create and start a queue manager. The queue manager is referred
to as qMgr in this task.
As part of this task you configure the telemetry (MQXR) service. The MQXR property settings are
stored in a platform-specific properties file: mqxr_win.properties. You do not
normally need to edit the MQXR properties file directly, because almost all settings can be
configured through MQSC admin commands or MQ Explorer. If
you do decide to edit the file directly, stop the queue manager before you make your changes. See
MQXR properties.
When the telemetry (MQXR) service is first started, it creates SYSTEM.MQTT.TRANSMIT.QUEUE.
It is created manually in this task, because SYSTEM.MQTT.TRANSMIT.QUEUE must exist before the telemetry (MQXR) service is started, to authorize access to it.
Set the default transmission queue for qMgr
When the telemetry (MQXR) service is first started, it does not alter the queue manager to make SYSTEM.MQTT.TRANSMIT.QUEUE the default transmission queue.
To make SYSTEM.MQTT.TRANSMIT.QUEUE the default transmission queue alter the
default transmission queue property. Alter the property using the MQ Explorer or with the command in Figure 1.
Altering the default transmission queue might interfere with your existing configuration. The
reason for altering the default transmission queue to SYSTEM.MQTT.TRANSMIT.QUEUE is
to make sending messages directly to MQTT clients
easier. Without altering the default transmission queue you must add a remote queue definition for
every client that receives IBM MQ messages; see Sending a message to a client directly.
Follow a procedure in Authorizing MQTT clients to access IBM MQ objects to create one or more user IDs.
The user IDs have the authority to publish, subscribe, and send publications to MQTT clients.
Verify the configuration by running the sample client.
For the sample client to work with your telemetry channel, the channel must authorize the client
to publish, subscribe, and receive publications. The sample client connects to the telemetry channel
on port 1883 by default. See also IBM MQ Telemetry
Transport sample programs.
Creating SYSTEM.MQXR.SERVICE manually
Figure 2 shows the runmqsc command to create the