[z/OS]

Objects and actions on z/OS®

The operations and control panels offer you many different types of object and a number of actions that you can perform on them.

The actions are listed on the initial panel and enable you to manipulate the objects and display information about them. These objects include all the IBM® MQ objects, together with some extra ones. The objects fall into the following categories.

Refer to Actions for a cross-reference table of the actions which can be taken with the IBM MQ objects.

Queues, processes, authentication information objects, namelists, storage classes and CF structures

These are the basic IBM MQ objects. There can be many of each type. They can be listed, listed with filter, defined, and deleted, and have attributes that can be displayed and altered, using the LIST or DISPLAY, LIST with FILTER, DEFINE LIKE, MANAGE, and ALTER actions. (Objects are deleted using the MANAGE action.)

This category consists of the following objects:
Channels

Channels are used for distributed queuing. There can be many of each type, and they can be listed, listed with filter, defined, deleted, displayed, and altered. They also have other functions available using the START, STOP and PERFORM actions. PERFORM provides reset, ping, and resolve channel functions.

This category consists of the following objects:
Cluster objects

Cluster objects are created automatically for queues and channels that belong to a cluster. The base queue and channel definitions can be on another queue manager. There can be many of each type, and names can be duplicated. They can be listed, listed with filter, and displayed. PERFORM, START, and STOP are also available through the LIST actions.

This category consists of the following objects:

Cluster channels and cluster queue managers do have the PERFORM, START and STOP actions, but only indirectly through the DISPLAY action.

Queue manager and security

Queue manager and security objects have a single instance. They can be listed, and have attributes that can be displayed and altered (using the LIST or DISPLAY, and ALTER actions), and have other functions available using the PERFORM action.

This category consists of the following objects:
Connection

Connections can be listed, listed with filter and displayed.

This category consists only of the connection object, CONNECT.

System
A collection of other functions. This category consists of the following objects:
The functions available are:

Actions

The actions that you can perform for each type of object are shown in the following table:

Table 1. Valid operations and control panel actions for IBM MQ objects
Object Alter Define like Manage (1) List or Display List with Filter Perform Start Stop
AUTHINFO X X X X X      
CFSTATUS       X        
CFSTRUCT X X X X X      
CHANNEL X X X X X X X X
CHSTATUS       X X      
CLNTCONN X X X X X      
CLUSCHL       X X X(2) X(2) X(2)
CLUSQ       X X      
CLUSQMGR       X X X(2) X(2) X(2)
CLUSRCVR X X X X X X X X
CLUSSDR X X X X X X X X
CONNECT       X X      
CONTROL       X   X X X
MANAGER X     X   X    
NAMELIST X X X X X      
PROCESS X X X X X      
QALIAS X X X X X      
QLOCAL X X X X X      
QMODEL X X X X X      
QREMOTE X X X X X      
QSTATUS       X X      
QUEUE X X X X X      
RECEIVER X X X X X X X X
REQUESTER X X X X X X X X
SECURITY X     X   X    
SENDER X X X X X X X X
SERVER X X X X X X X X
SVRCONN X X X X X   X X
STGCLASS X X X X X      
SYSTEM       X   X X X
Note:
  1. Provides Delete and other functions
  2. Using the List or Display action