[z/OS]

Lock manager codes (X'D3')

If a lock manager reason code occurs that is not listed here, an internal error has occurred. Collect the following diagnostic items and contact IBM® Support.

Diagnostics

  • A description of the actions that led to the error or, if applicable, either a listing of the application program or the input string to a utility program that was being run at the time of the error.
  • The console output for the period leading up to the error.
  • The queue manager job log.
  • The system dump resulting from the error.
  • If you are using CICS®, the CICS transaction dump output.
  • Appropriate IBM MQ, z/OS®, Db2®, CICS, and IMS service levels.
00D301F1

An attempt to obtain storage was unsuccessful. This is probably because there is insufficient storage in your region.

System action

The current execution unit terminates with completion code X'5C6'.

System programmer response

Check that you are running in a region that is large enough. If not, reset your system and restart the queue manager. If this is not the cause of the problem, collect the items listed in Diagnostics and contact IBM Support.

00D301F2

An attempt to obtain storage was unsuccessful. This is probably because there is insufficient storage in your region.

System action

The current execution unit terminates with completion code X'5C6'.

System programmer response

Check that you are running in a region that is large enough. If not, reset your system and restart the queue manager. If this is not the cause of the problem, collect the items listed in Diagnostics and contact IBM Support.

00D301F3

An attempt to obtain storage was unsuccessful. This is probably because there is insufficient storage in your region.

System action

The current execution unit terminates with completion code X'5C6'.

System programmer response

Check that you are running in a region that is large enough. If not, reset your system and restart the queue manager. If this is not the cause of the problem, collect the items listed in Diagnostics and contact IBM Support.

00D301F4

An attempt to obtain storage was unsuccessful. This is probably because there is insufficient storage in your region.

System action

The current execution unit terminates with completion code X'5C6'.

System programmer response

Check that you are running in a region that is large enough. If not, reset your system and restart the queue manager. If this is not the cause of the problem, collect the items listed in Diagnostics and contact IBM Support.

00D301F5

An attempt to obtain storage was unsuccessful. This is probably because there is insufficient storage in your region.

System action

The current execution unit terminates with completion code X'5C6'.

System programmer response

Check that you are running in a region that is large enough. If not, reset your system and restart the queue manager. If this is not the cause of the problem, collect the items listed in Diagnostics and contact IBM Support.

00D302F1, 00D302F2, 00D302F3, 00D302F4, 00D302F5, 00D303F1, 00D303F2, 00D303F3, 00D304F1, 00D305F1, 00D306F1

An internal error has occurred.

System action

The current execution unit terminates with completion code X'5C6'.

System programmer response

Collect the items listed in Diagnostics and contact IBM Support.

00D31094, 00D31095, 00D31096, 00D31097

An internal error has occurred.

System action

The current execution unit terminates with completion code X'5C6'. In some cases, the queue manager might terminate with completion code X'6C6'.

System programmer response

Collect the items listed in Diagnostics and contact IBM Support.