Powering on
Perform the following to turn on IBM® Integrated Analytics System.
Procedure
-
Check that the 4 main power cables are connected to the data center drops.
Note: When powering on the appliance, wait at least 60 seconds after applying power to the PDUs for it to complete self-test, and verify that all LEDs are green. If disconnecting and reconnecting power from PDUs with the appliance running, disconnect only one PDU at a time. When reconnecting and powering on that PDU, before disconnecting another PDU, wait at least 60 seconds after applying power to the PDU for it to complete self-test, and verify that all LEDs are green.
- Locate the PDUs in the rear of the rack in rack slots U33 through U36.
-
Switch the circuit breakers to ON on all PDUs.
PDU Circuit Breakers
- Power on the nodes by pressing the power buttons of each node.
-
When all nodes have booted, log into the master node as apuser and type the commands:
apstart