Task 6: Completing the initial program load

You can learn how to complete the initial program load (IPL).

  1. Press F3 to continue the IPL.
  2. The Edit Rebuild of Access Paths display is shown during the IPL process (attended mode) when system access paths are marked for rebuild.

    The Task 2: Editing the rebuilding of access paths topic describes how to interpret and update this display.

                       Edit Rebuild of Access Paths
                                                          05/12/90  13:49:34
     
    IPL threshold . . . . . . . . . . . . . 50   0-99
     
    Type sequence, press Enter.
    Sequence:  1-99, *OPN, *HLD
     
                       ------------Access Paths----------  Unique  Rebuild
    Seq   Status       File        Library     Member      Keyed   Time
    25__  IPL          QAPZSYM2    QSYS        QAPZSYM2    NO      00:00:01

    A status message is sent to notify the user that the system is performing access path recovery.

  3. Make any changes and press the Enter key.
    If you have made changes, the Edit Rebuild of Access Paths display is shown again confirming your changes or showing your error messages. Repeat this step until the Display Access Path Status display is shown or the IPL continues.
  4. The Display Access Path Status display is updated every 5 seconds while the system is rebuilding access paths.
                         Display Access Path Status
     
    IPL Threshold . . . . . . : 50
     
              ----------Access Paths----------   Rebuild     Current
    Status    File        Library    Member      Build Time  Run Time
    RUN       QAPZSYM2    QSYS       QAPZSYM2    00:00:01    00:00:01
    JRN       QAPZREQ2    QSYS       QAPZREQ2    00:00:01
    SYS       QASULE03    QSYS       QASULE03    00:00:01
    IPL       QASULE01    QSYS       QASULE01    00:00:01

    If you want to make changes, press F12 (Cancel) to return to the Edit Rebuild of Access Paths display. If all access paths are rebuilt or you no longer want to see the display, press F3 (Exit and continue IPL).

    Note: The rebuild of access paths requires system memory. It is suggested that you avoid a high level of system activity so that the rebuild of access paths can complete.
  5. The Edit Check Pending Constraints display is shown if referential constraints need to be verified.

    Task 3: Editing check pending constraints topic describes how to interpret and update this display.

                            Edit Check Pending Constraints
                                                                xx/xx/xx  10:09:27
    Type sequence, press Enter.
    Sequence:  1-99, *HLD
     
                           ----------Constraints-----------  Verify    Elapsed
    Seq   Status           Cst       File        Library     Time      Time
     
    75__  AFTIPL       CSTF1       FILE567890  LIB4567890  00:00:56  00:00:00
  6. Make any changes and press the Enter key.
    The Edit Check Pending Constraints display is shown again confirming your changes or showing your error messages if you have made changes. Repeat this step until the Display Constraint Status display is shown or the IPL continues.
  7. The Display Constraint Status display is updated every 5 seconds while the system is verifying constraints.
                         Display Constraint Status
     
    IPL Threshold . . . . . . : 50
     
              ----------Constraints-----------   Verify      Elapsed
    Status    Constraint  File       Library     Time        Time
    RUN       CUST1       CUSTMAST   CUSTLIB     00:00:04    00:00:01
    RUN       CUST2       CUSTMAST   CUSTLIB     00:00:05    00:00:01
    IPL       ORDHST1     ORDHIST    ORDLIB      00:00:23    00:00:00

    If you want to make changes, press F12 (Cancel) to return to the Edit Check Pending Constraints display. Press F3 (Exit and continue IPL) if all constraints are verified or you no longer want to see the display.

  8. Press the Enter key if QSYSOPR messages are displayed.
  9. You might receive A900 2000 on the control panel for the system or logical partition, or message CPF0975, Console did not vary on, on the console display.
    This occurs if your system configuration was lost and you have disabled automatic configuration. The system has created device description QCONSOLE to allow you to continue the restore operation. You might also receive SRC A900 2000 if you perform an IPL when the QIPLTYPE system value is set to 2. Do not create a user-defined device description for the console display. This can cause unpredictable results.

    If you receive this message, perform the steps that are described in Recovering from SRC A900 2000 before continuing.

  10. If you restored from the distribution media by using a 1/4-inch cartridge tape drive, the light on the tape drive might still be on.
    After the system has finished restoring the operating system, you can remove the tape while the light is on.