Recovering from SRC 6xxx 7051

You are receiving this message because the compressed device and the compression input/output adapter (IOA) are not compatible.

  1. Did you remove the disk unit from another system?
    Yes
    No
    Go to step 6.
  2. Was it removed from the auxiliary storage pool (ASP) of the other system?
    Yes
    No
    Go to step 4.
  3. Stop compression on the disk unit.
    This ends the procedure.
  4. Do you want to save the data that is on the disk unit?
    Yes
    No
    Stop compression on the disk unit.

    This ends the procedure.

  5. Return the disk unit to its original system and IOA and perform the following tasks:
    1. Remove the disk unit from the ASP.
    2. Stop compression on the disk unit.

    Reinstall the disk unit to this system.

    This ends the procedure.

  6. The input/output processor (IOP) or IOA that you are using is not compatible with the disk unit.
    Do you want to save the data that is on the disk unit?
    Yes
    No
    Stop compression on the disk unit.

    This ends the procedure.

  7. If you come here from another procedure, return there and follow the procedure, otherwise contact your next level of support.

    This ends the procedure.