Auditing system values: Activate object auditing (QAUDCTL (*OBJAUD))

The Activate object auditing system value is also known as QAUDCTL (*OBJAUD). You can use this system value to have the system write a record to the audit journal each time an object being audited is accessed by a user.

Quick reference
Location From IBM Navigator for i, select Configuration and Service > System Values. Right-click on Auditing and click Properties, then switch to the Security Audit Control tab.
Special authority Audit (*AUDIT).
Notes:
  1. To view this system value, you must have Audit (*AUDIT) or All object (*ALLOBJ) special authority.

    If you do not have the required authority, the Auditing category is not displayed in IBM Navigator for i. If you access this system value in the character-based interface, the Not available (*NOTAVL) value is displayed.

  2. To change this system value, you must have Audit (*AUDIT) special authority.
Default value Deselected. Do not activate object auditing.
Changes take effect Immediately.
Lockable Yes.
Lockable system value
(See Lock function of security-related system values for details.)

What can I do with this system value?

You can specify whether the system writes a record to the audit journal each time an object being audited is accessed by a user.

Actions against objects that have an object audit value other than none (*NONE) are audited. To set an object's audit value in the character-based interface, use the Change Audit (CHGAUD) command or the Change Object Audit (CHGOBJAUD) command.