Configuring DS8000 Full System HyperSwap
For System i® high availability solutions using HyperSwap®, detection of the HyperSwap configuration is automatic on the System i machine after appropriate configuration has been performed on the IBM® System Storage® external storage units.
The steps assume knowledge of configuring and managing an IBM System Storage DS8000®. For information about using an IBM System Storage DS8000 unit, see Copy Services in the IBM System Storage DS8000 Information Center.
To configure HyperSwap, follow these steps:
- Create LUNs on the source DS8000.
- Assign LUNs on source DS8000 to the System i machine.
- Create LUNs on the target DS8000. Do not assign them to the System i until after Metro Mirror is configured.
- Configure Metro Mirror between the source and target DS8000.
- Assign the LUNs on the target DS8000 to the same System i machine.
- Verify the HyperSwap configuration with the Display HyperSwap Status (DSPHYSSTS) command.
To understand how HyperSwap interfaces with affinity, see Defining HyperSwap Affinity.