Advanced node failure detection

Start of changeCluster Resource Services can now use Hardware Management Console (HMC) or a Virtual I/O Server (VIOS) partition on an Integrated Virtualization Manager (IVM) managed server to detect when a cluster node fails.End of change

Start of changeDetection of node failures can be accomplished using a HMC or IVM. End of change

Start of changeTo add advanced node failure detection for HMC with a CIM server or IVM, which uses a CIM server, a cluster node that is configured with a cluster monitor must install the following software.
  • IBM® i option 33, IBM Portable Application Solutions Environment for i
  • 5733-SC1, IBM Portable Utilities for i
  • 5733-SC1 option 1, OpenSSH, OpenSSL, zlib
  • 5770-UME, IBM Universal Manageability Enablement for i
  • Start of changeHMC version must be V8R8.5.0 or earlier. This is the last version of HMC to support the CIM server.End of change
End of change
Start of changeTo add advanced node failure detection for HMC with a representational state transfer (REST) server. A cluster node that is configured with a cluster monitor must have the following software installed.
  • IBM i option 33, IBM Portable Application Solutions Environment for i
  • IBM i option 3, Extended Base Directory Support
  • 5733-SC1, IBM Portable Utilities for i (Only required for initial configuration of a cluster monitor.)
  • 5733-SC1 option 1, OpenSSH, OpenSSL, zlib (Only required for initial configuration of a cluster monitor.)
  • HMC version must be V8R8.5.0 or later. This is the first version of HMC to support the REST server.
  • PowerHA® new function cluster monitor HMC REST support PTFs
End of change