IASP-based HyperSwap® enviroments require
both HyperSwap and logical unit number (LUN)
switching configuration.
If necessary, use HyperSwap independently
as a disk protection solution in a single-system environment without any LUN
configuration. This has limited uses.
Inside a high availablity environment with IASPs, both HyperSwap and LUN switching must be configured. The IASPs in
the HyperSwap configuration require LUN
volume groups separate from any of the SYSBAS LUNs. Any secondary IASPs in the same
HyperSwap relationship associate
with the primary IASP only. Primary and secondary IASPs cannot split into separate
relationships. Other primary IASPs or user defined file system (UDFS IASP) outside
of the HyperSwap environment have
seperate defined relationships.
IBM i high availability solutions using DS8000
HyperSwap automatically detect the HyperSwap IASPs after the DS8000 is configured appropriately.
To configure HyperSwap for use with IASPs, follow these
steps:
- Create LUNs on the source DS8000
system.
- Assign those LUNs on the source DS8000
to the System i® partition.
Note: The IASP LUNs must be in separate volume groups from any SYSBAS LUNs, on
both the source and target DS8000.
- Create LUNs on the target DS8000 but
do not assign them to the IBM i until
after the Metro Mirror has been configured.
Note: The IBM i device driver ensures
data consistency for HyperSwap
switchover and failover operations. Do not use Metro Mirror consistency
groups here.
- Configure Metro Mirror between the source and target DS8000 with the mkpprcpath
command on the DS8000 from the DSCLI.
- Start Peer-to-Peer Remote Copy (PPRC) with the mkpprc
command on the DS8000 from the DSCLI.
- Assign the LUNs on the target DS8000
to the same IBM i partition.
- Verify the HyperSwap configuration
with the Display HyperSwap Status
(DSPHYSSTS) command. The status of the HyperSwap drive pairs configured should display in the
DSCLI
- If your established HyperSwap
environment requires additional disk units for more cacpacity, complete the
following procedure to add units to an existing IASP in a HyperSwap
environment:
- For new disk units to be added to the IASP, pause PPRC with the
pausepprc command on the DS800 from the
DSCLI
- Stop replication with the Change HyperSwap Status command,
CHGHYSSTS OPTION(*STOP) ASPDEV(iasp-name).
- Add the new units to the IASP with the System Service Tools
(STRSST) command.
- Resume replication with the Change HyperSwap Status command,
CHGHYSSTS OPTION(*START) ASPDEV(iasp-name).
The expanded storage in your HyperSwap environment on your IBM i partition is configured for switching.