INCORROUT procedure
- If the data or records were repeated endlessly, use the LOOP procedure instead of the INCORROUT procedure to create your keyword string.
- Use INCORROUT as your type-of-failure keyword.
- If the error was detected because of incorrect or missing output from an assembly
that otherwise completed successfully, select a modifier keyword from the following table to
describe the type of error in the output.
Modifier Keyword Type of Incorrect Output DUPLICATE Some data or records were duplicated, but were not repeated endlessly. INVALID The output that appeared was incorrect or not as expected. MISSING Some expected output was missing. - Select another modifier keyword from the following table to describe
the portion of the output in which the error occurred.
Modifier Keyword Portion of Output in Error ADATA Associated data file. DXREF DSECT cross-reference. ESD External symbol dictionary listing. If the external symbol dictionary part of the object program is in error, use the OBJECT keyword followed by the ESD keyword. GOFF (z/OS® and CMS) Machine-language generalized object program. MESSAGE Diagnostic message. MXREF Macro and copy code source summary, and macro and copy code cross-reference. OBJECT Machine-language object program. RLD Relocation Dictionary listing. If the relocation dictionary part of the object program is in error, use the OBJECT keyword followed by the RLD keyword. RXREF General Purpose Register Cross Reference SOURCE Source listing. STAT Statistics and error listing. TERM Progress and diagnostic messages on SYSTERM data set for z/OS, on the terminal for CMS, or on SYSLOG for z/VSE®. UMAP USING map. XREF Ordinary Symbol and Literal Cross Reference listing. - Determine with which assembler options the failure occurs. If
the failure occurs only when using certain options, indicate those
options in the keyword string. Select the applicable modifier keyword
from the list shown in Assembler options. For example, if you think that the assembler has given an incorrect Ordinary Symbol and Literal Cross Reference section of the listing when assembling with the XREF(FULL) option, your set of keywords, so far, consists of:
Component Identification: 569623400 Release Level: R600 Type of Failure: INCORROUT Modifiers: INVALID XREF FULL
- Continue with Step 4. System-type keyword.