FORCE_LOG_LIMITED

FORCE_LOG_LIMITED enables you to force limited audit logging by removing sensitive information from data sent to the Guardium® appliance by the S-TAP®.

Required
No
Default
N
Permitted Values
N, Y
Description

Set to Y to force limited audit logging by removing sensitive information from data sent to the Guardium appliance by the S-TAP. This keyword restricts the collection of sensitive data by enabling the active policy control over the collection of host variables.

If this keyword is set to N, the collection of host variables is controlled by the host variable settings in the active policy.

If this keyword is set to Y:
  • The policy setting for collection of host variables is ignored and host variables are not collected.
  • When using this keyword, you must also set APPLIANCE_PORT to 16023. Port 16023 is used for AT-TLS-configured encrypted communications. If APPLIANCE_PORT is not set to 16023, the S-TAP agent generates a log message indicating the configuration inconsistency, and shuts down.
Notes
None
Syntax
FORCE_LOG_LIMITED(N)
Example
FORCE_LOG_LIMITED(Y)