Use this task to run advanced verification on individual inspection engines on a specific
S-TAP client host, and to add individual inspection engines to advanced verification.
Procedure
-
Access .
-
Click anywhere in the row of the S-TAP.
The window refreshes with the individual
inspection engines of this host.
-
To output immediate verification results, take the following steps:
-
Click one inspection engine, and click Advanced Verify.
-
12.0 Optionally, under Datasource, select Show only matching S-TAP host or
select a name from the Name list to search for a specific inspection engine.
-
Click Verify.
The S-TAP Verification Results opens. Failed checks are shown first, with
recommendations for next steps. Checks that succeeded are shown in a collapsed section at the end of
the list. In some situations, it might be useful to review the successful checks in order to choose
among possible next steps.
-
By default, the system waits five seconds before it displays verification results. If your
network latency is high, five seconds might not be enough time to receive the expected response from
the database server. If
you need to allow more time, you can use the store stap network_latency CLI
command to change the period.
-
To add to or remove individual inspection engines to the verification schedule:
-
Select one or more inspection engines.
-
Click Add to Schedule or Remove from
Schedule
What to do next
View the results of schedules verification in the S-TAP Verification
page ().