Table 1. FamMonitor GIM installation parameters
GIM parameter Description
FAMMONITOR_SQLGUARD_IP The Guardium IP.
FAMMONITOR_ADDITIONAL_SQLGUARD_IPS Additional Guardium® hostnames or IP addresses. If there is a failover, the FAM agent attempts to connect to the next appliance on the list.
FAMMONITOR_ENABLED
  • 0: FamMonitor is stopped after installation.
  • 1: FamMonitor is started after installation.
FAMMONITOR_FAM_NORDP Determines whether Guardium records the remote client IP address or the the server IP address as the client IP address in its file events, for users connected by remote desktop.
  • 0: Guardium records the remote client IP address.
  • 1: Guardium records the server IP address as the client IP address.
Default=0
FAMMONITOR_INSTALL_DIR Required. This is the install directory. The default install path is program files\ibm\fammonitor
FAMMONITOR_INSTALLER_LOG_DIR Specifies the location for storing the FamMonitor installer log files. Use this parameter if you want don't want to use the default location (C:\Program Files\IBM\Windows Fam Monitor).
FAMMONITOR_TAP_IP The local/client IP. Required for unattended installation.
FAMMONITOR_QUIET Install silently. (Does not require a value.)
FAMMONITOR_CMD_LINE Adds key and value to Famonitor config file. Format: key1=value1 key2=value2, separated by space between pairs of key-value.