Windows: S-TAP GIM installation parameters
Understand the parameters (each with a short description) that are typically used in your GIM installation.
Depending on which protocol you are using, parameters are listed in
either Editing the protocol 7 and protocol 8 S-TAP configuration parameters or Editing the protocol 8 S-TAP configuration parameters.
CAUTION:
Do not modify
advanced parameters unless you are an expert user or you are consulting with IBM Technical
Support.
Attention: If a parameter is available through both the GIM and the command
line interface (CLI), then the GIM parameter,
including any defaults, always overwrites any value that is available from
WINSTAP_CMD_LINE.
GIM parameter | Description |
---|---|
QUIET | Install silently. (Does not require value) |
WINSTAP_INSTALL_DIR | The installation directory. The default installation path is C:\Program Files\IBM\Windows S-TAP |
GIM parameter | Description |
---|---|
WINSTAP_AUTO_DISCOVERY | Controls auto-discovery of database instances. When enabled during
installation, the agent discovers database instances on the server, populates inspection engines,
and updates the guard_tap.ini configuration files. The parameter value is 1
during a fresh installation and changes to 0 after the initial installation. For more information,
see Windows: Auto discovery of database instances during installation and upgrade. Valid values:
|
WINSTAP_ENABLED |
Enables or disables S-TAP and its services. Default is enabled (1). |
WINSTAP_ENABLEGAM | Enables the Guardium Agent Monitor service (GAM). Default is disabled (0). |
WINSTAP_INSTALLER_LOG_DIR | Specifies the location for storing the S-TAP installer log files. Use this parameter if you don't want to use the default location (C:). |
WINSTAP_SQLGUARD_IP | The SQLGUARD IP. You can set up multiple appliances by specifying this parameter multiple times, each with a unique value. |
WINSTAP_TAP_IP | The local/client IP. Required for unattended installation. |
GIM parameter | Description |
---|---|
WINSTAP_TCP_DRIVER_INSTALLED | To use the TCP driver, set
WINSTAP_TCP_DRIVER_INSTALLED=1 (the default). To disable the TCP driver, set this parameter to 0. |
WINSTAP_NAMED_PIPE_DRIVER_INSTALLED | To use the named pipe driver, set
NAMED_PIPE_DRIVER_INSTALLED=1 (the default). Specifies the
named pipe that is used by MS SQL Server for local access. If a named pipe is used, but nothing is
specified in this parameter, S-TAP attempts to retrieve the named pipe name from the registry. In rare cases, the S-TAP named pipes driver can interact with other third-party software in ways that slow the server down. To turn off the named pipes driver, set this parameter to 0. The named pipes driver is removed at the next system reboot. Note: If you turn off the named pipes driver, then the S-TAP does not capture named pipes traffic. |
WINSTAP_DB2_TAP_INSTALLED | Enables sniffing Db2 shared memory traffic. |
WINSTAP_DB2_EXIT_DRIVER_INSTALLED | Enables Db2 Integration with S-TAP. |
WINSTAP_ORA_DRIVER_INSTALLED | Enables sniffing Oracle ASO and SSL traffic. |
GIM parameter | Description |
---|---|
WINSTAP_LOAD_BALANCER_IP | Required if you are configuring enterprise load balancing. If blank, enterprise load
balancing is disabled. The IP address or hostname of the central manager or managed unit this S-TAP uses for load balancing. Dynamic parameter. When you modify the value in the guard_tap.ini, you do not need to restart the S-TAP for the updated values to take effect. |
WINSTAP_INITIAL_BALANCER_TAP_GROUP | The name of the S-TAP group that this S-TAP belongs to, for enterprise load balancing. |
WINSTAP_INITIAL_BALANCER_MU_GROUP | The name of the managed unit group that the app-group is associated with. Requires a defined LB-APP-GROUP. The managed unit group must exist on the central manager before it can be used during installation of the S-TAP. |
WINSTAP_LOAD_BALANCER_NUM_MUS | The number of managed units the enterprise load balancer allocates for this S-TAP. |
Note: S-TAP parameters
cannot be changed via the interactive installer during upgrade. After you upgrade, you can change
S-TAP
paramters either from the Guardium UI or
by using the update_stap_config
API.