Discovery parameters

The discovery parameters define the behavior of the auto-discovery feature, for discovering database instances and sending the results to the current active S-TAP.

These parameters are stored in the [TAP] section of the S-TAP properties file. For a full description of the feature, see Windows: Discover database instances.

Attention: These are advanced parameters and should be modified only by IBM Technical Support.
Attention: If a parameter is available through both the GIM and the command line interface (CLI), then the GIM parameter, including any defaults, always overwrites any value that is available from WINSTAP_CMD_LINE.
GIM guard_tap.ini Default value Description Protocol version
WINSTAP_AUTO_DISCOVERY AUTO_DISCOVERY 0 Enables auto discovery of database instances, populates inspection engines, and updates guard_tap.ini at S-TAP start. Auto discovery runs once at the time of S-TAP installation and does not automatically repeat. The parameter value is 1 upon a fresh install and changes to 0 after the initial discovery. When set to 1, auto-discovery overwrites user modifications to the inspection engines configurations. Use with caution. Valid values:
  • 0: disabled
  • 1: enabled
7 and 8
WINSTAP_DISCOVERY_INTERVAL DISCOVERY_INTERVAL 24 The time interval, in hours, at which the S-TAP reports its discovered DB instances to collector. Valid values:
  • 0: disabled
  • Negative integer: Interval in minutes in the range -5 through -1440 (5 - 1440 minutes)
  • Positive integer: Interval in hours in the range 1 - 24
Remember: For Protocol 8 only: Dynamic parameter. When you modify the value in the guard_tap.ini, the S-TAP does not need restarting for the updated values to take effect.
7 and 8
WINSTAP_DISCOVERY_PORT DISCOVERY_PORT 8443 S-TAP uses this port to connect to the Guardium system. Valid values: 10244-65535. 7 and 8