GDDM-GKS V1R1 Programming Guide and Reference
Previous topic | Next topic | Contents | Index | Contact z/OS | Library | PDF | BOOK


Relevant for input and output/input workstations

GDDM-GKS V1R1 Programming Guide and Reference
SC33-0334-00




 Entry name
                     
 Coordinate
 system
 Permitted
 values
 Data
 type
 Initial
 value
 Locator device
 number(1)
 --
           
 1 ... n
                
 I
       
 --
             
 Default initial
 locator position(1)
 WC
           
 --
                
 P
       
 0.1, 0.1
             
 Number of available
 prompt and echo
 types(1)
 --
           
           
 1 ... n
                
                
 I
       
       
 --
             
             
 List of available
 prompt and echo
 types(1)
 --
           
           
 -n ... -1, 1
 ... n
                
 (n) I
       
       
 --
             
             
 Default echo
 area(1)
 DC
           
 --
                
 (4) R
       
 --
             
 Default locator
 data record(1)
 --
           
 --
                
 D
       
 --
             
 Stroke device
 number(2)
 --
           
 1 ... n
                
 I
       
 --
             
 Maximum input
 buffer size(2)
 --
           
 64 ... n
                
 I
       
 --
             
 Number of available
 prompt and echo
 types(2)
 --
           
           
 1 ... n
                
                
 I
       
       
 --
             
             
 List of available
 prompt and echo
 types(2)
 --
           
           
 -n ... -1, 1
 ... n
                
 (n) I
       
       
 --
             
             
 Default echo
 area(2)
 DC
           
 --
                
 (4) R
       
 --
             
 Default stroke data
 record(2,3)
 --
           
 --
                
 D
       
 --
             
 Input buffer
 size(2,3)
 --
           
 1 ... n
                
 I
       
 64
             
 Valuator device
 number(4)
 --
           
 1 ... n
                
 I
       
 --
             
 Default initial
 value(4)
 --
           
 --
                
 R
       
 --
             
 Number of available
 prompt and echo
 types(4)
 --
           
           
 1 ... n
                
                
 I
       
       
 1
             
             
 List of available
 prompt and echo
 types(4)
 --
           
           
 -n ... -1, 1
 ... n
                
 (n) I
       
       
 1
             
             
 Default echo
 area(4)
 DC
           
 --
                
 (4) R
       
 --
             
 Default valuator
 data record(4)
 --
           
 --
                
 D
       
 --
             
 Low value(4,5)  --  --  R  -1E18
 High value(4,5)  --  --  R  1E18
 Choice device
 number(6)
 --
           
 1 ... n
                
 I
       
 --
             
 Maximum number of
 choice
 alternatives(6)
 --
           
           
 1 ... n
                
                
 I
       
       
 --
             
             
 Number of available
 prompt and echo
 types(6)
 --
           
           
 1 ... n
                
                
 I
       
       
 1
             
             
 List of available
 prompt and echo
 types(6)
 --
           
           
 -n ... -1, 1
 ... n
                
 (n) I
       
       
 1
             
             
 Default echo
 area(6)
 DC
           
 --
                
 (4) R
       
 --
             
 Default choice data
 record(6)
 --
           
 --
                
 D
       
 --
             
 Pick device
 number(7)
 --
           
 --
                
 I
       
 --
             
 Number of available
 prompt and echo
 types(7)
 --
           
           
 1 ... n
                
                
 I
       
       
 1
             
             
 List of available
 prompt and echo
 types(7)
 --
           
           
 -n ... -1, 1
 ... n
                
 (n) I
       
       
 1
             
             
 Default echo
 area(7)
 DC
           
 --
                
 (4) R
       
 --
             
 Default pick data
 record(7)
 --
           
 --
                
 D
       
 --
             
 String device
 number(8)
 --
           
 1 ... n
                
 I
       
 --
             
 Maximum input
 buffer size(8)
 --
           
 72 ... n
                
 I
       
 72
             
 Number of available
 prompt and echo
 types(8)
 --
           
           
 1 ... n
                
                
 I
       
       
 --
             
             
 List of available
 prompt and echo
 types(8)
 --
           
           
 -n ... -1, 1
 ... n
                
 (n) I
       
       
 --
             
             
 Default echo
 area(8)
 DC
           
 --
                
 (4) R
       
 --
             
 Default string data
 record(8)
 --
           
 --
                
 D
       
 --
             
 Input buffer
 size(8)
 --
           
 1 ... n
                
 I
       
 72
             
 Initial cursor
 position(8)
 --
           
 1 ... n
                
 I
       
 1
             


   Notes:

1. These values apply to every locator class logical input device.

2. These values apply to every stroke class logical input device.

3. The default stroke data record must contain at a minimum the input buffer size.

4. These values apply to every valuator class logical input device.

5. The default valuator data record must contain these values at a minimum.

6. These values apply to every choice class logical input device.

7. These values apply to every pick class logical input device.

8. These values apply to every string class logical input device.

Go to the previous page Go to the next page



Copyright IBM Corporation 1990, 2012