Expansion rack
This section answers questions that are related to expansion rack in IBM Fusion HCI System.
-
- On a base rack with a 4+2p scale cluster, can we add only 3 storage nodes from the expansion rack with 6 storage nodes to OpenShift® Container Platform and reserve the rest of the nodes for future consumption?
- No. To maintain the scale cluster quorum, on a 4+2p scale cluster, all 6 storage nodes must be added to the cluster.
-
- Is rack Expansion support on Data Foundation cluster.
- Yes, it supports on Data Foundation cluster. The auxiliary rack must have minimum three storage nodes, and all the NVMe disks size must be of same size across all the nodes.
-
- If storage nodes on the initial rack have 4 NVMe drives per node. Can I add nodes with 2 NVMe drives per node to the expansion racks of the cluster?
- Yes, for Data Foundation. The storage nodes in the
initial and expansion racks can have different numbers of NVMe drives.
For example, the initial rack can have 6 NVMe drives in the storage nodes, and the storage nodes in the expansion rack can have 4 NVMe drives.
-
- Can I expand the rack only to increase the compute capacity by using IBM Fusion HCI System expansion multi-rack?
- No, it is not possible to add compute capacity without adding the minimum of six storage nodes. To increase the compute capacity, add them along with minimum required storage nodes.