BMYSS01038W

The scale pods are not up and running.

Severity

Warning

Problem description

It indicates that the scale pods are not up and running. The scale core pods must be up and running for the scale upgrade to be successful.

Recommended actions

Do the following steps to resolve the issue:
  1. Check the logs of the ibm-spectrum-scale-controller-manager pod in the ibm-spectrum-scale-operator for any errors and take an appropriate action to resolve them.
  2. Check the logs of the isf-storage-operator pod in the isf-spectrum-fusion-ns namespace for any errors and take an appropriate action to resolve them.

    The upgrade operation resumes automatically after the issue is resolved.

  3. If the issue persists for a long time, then collect the Global Data Platform logs and contact IBM support .