BMYSS01037W

Storage cluster status is degraded since some of the IBM Storage Scale or IBM Storage Scale CSI pods are down.

Severity

Warning

Problem description

It indicates that the storage cluster status is degraded since some of the IBM Storage Scale or IBM Storage Scale CSI pods are down. The storage cluster status needs to be healthy for a successful upgrade.

Recommended actions

Do the following steps to resolve the issue:
  1. After all the nodes are updated, wait for storage cluster status to turn healthy.
  2. If storage cluster status is unhealthy even after waiting, then check the logs of the isf-storage-operator pod in the isf-spectrum-fusion-ns namespace for any errors and take an appropriate action to resolve them.
  3. Check the logs of the ibm-spectrum-scale-controller-manager pod in the ibm-spectrum-scale-operator namespace for any errors and take an appropriate action to resolve them.

    The upgrade operation resumes automatically after the issue is resolved.

  4. If the issue persists for a long time, then collect the Storage logs and contact IBM support .