BMYXC0022
Refer to error conditions for a specific condition.
Error conditions
The error message can be for the following conditions:
- The operating System status changed to offline.
- The server is restarted with a chassis control command.
- The server is powered with a chassis control command.
- User LXPM has mounted the file tdm_image.img from local.
- The port 1 of the PCIe device Intel I350 1GbE RJ45 4-port OCP Ethernet Adapter onboard is linked down.
- Disk related errors. For example, disk removal, addition, rebuild, hot spare and so on.
Severity
Informational, warning, or critical
Note: The critical severity occurs whenever there are disk
related errors.
User action
Do the following steps to diagnose the error:- Error conditions one, two, three, and four are informational messages, and no action is required.
- For error condition five, ensure that you check the network cable and power cable connectivity to the respective ports.
- For error condition six, collect the System health check and Nodes logs and contact IBM support .