BMYXC0022

Refer to error conditions for a specific condition.

Error conditions

The error message can be for the following conditions:
  1. The operating System status changed to offline.
  2. The server is restarted with a chassis control command.
  3. The server is powered with a chassis control command.
  4. User LXPM has mounted the file tdm_image.img from local.
  5. The port 1 of the PCIe device Intel I350 1GbE RJ45 4-port OCP Ethernet Adapter onboard is linked down.
  6. Disk related errors. For example, disk removal, addition, rebuild, hot spare and so on.

Severity

Informational, warning, or critical
Note: The critical severity occurs whenever there are disk related errors.

User action

Do the following steps to diagnose the error:
  1. Error conditions one, two, three, and four are informational messages, and no action is required.
  2. For error condition five, ensure that you check the network cable and power cable connectivity to the respective ports.
  3. For error condition six, collect the System health check and Nodes logs and contact IBM support .