BMYCO0015
Hardware validation error.
Error conditions
The error message can be for the following conditions:
- Hardware validation
-
- The new node model is not recognized.
- The provided RU number is invalid because it is not sequentially incremental. Stack up the new node in a bottom-up direction.
- Provide a valid RU.
- Unable to read network CRS, internal runtime error".
- Unable to create remote OneCli connection with IMM using LLA.
- Management switch port is not up for the switch. If the port is not up even after 20 minutes, check cable connectivity.
- Unable to read port status from any switch to validate the cabling.
- High speed switch port is not up for the switch hence retrying connectivity. If the port is not up even after 20 minutes, check cable connectivity.
- Unable to read the port status of switch.
- Unable to read port status from any switch to validate the cabling.
- Unable to read/parse user_config secret.
Severity
Critical
User response
Collect Nodes logs and contact IBM support .