1689 Array MDisk has lost redundancy.

Explanation

Array MDisk has lost redundancy. The RAID 5 system is missing a data drive.

User response

Replace the missing or failed drive.
Possible reason - FRUs or other:
  • Drives removed or failed (100%)
  • Rebuild might be incomplete or paused.